Home | Online Ordering | Products | Engineering & Construction | LPG Trucks & Fabrication | TEECO Topics | Contact TEECO | About TEECO |
Products>>Section A- RegO / ECII>>Pressure Relief Valves and Relief Valve Manifolds>>Page A-19
|
|
|
|
Fully Internal "Pop-Action" Pressure Relief Valves for DOT Fork Lift Cylinders
Designed specifically for use as a primary relief valve on forklift cylinders, the 8545AK reduces the possibility of improper functioning of the relief mechanism due to foreign material build up. All guides, springs, stem and adjusting components are located inside the cylinder - removed from the direct exposure of foreign materials and debris from the atmosphere.
NFPA Pamphlet #58 requires that: "All containers used in industrial truck (including forklift truck cylinders) service shall have the container pressure relief valve replaced by a new or unused valve within 12 years of the date of manufacture of the container and each 10 years thereafter."
| Part Number | Container Type | Start to Discharge Setting (PSIG) | Container Connection M. NPT | Flow Capacity SCFM / Air** | Accessories (Order Separately) | Order Relief Valve | ||
| (ECII Rated at 480 PSIG) | Protective Cap (Included) | Deflectors*** | ||||||
|
45° Elbow |
90° Elbow | |||||||
| 8545AK | DOT | 375 | 3/4" | 400* | 7545-40 | 7545-14A | 7545-12 | |
* Classified by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders.
Meets requirements for use on DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas.
** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce flow as discussed in forewording information.
*** Order protective cap #8545-41 or 7545-40.
7545-12 90° Adapter
|
7545-14A 45° Adapter
|
|
Semi-Internal "Pop-Action" Pressure Relief Valves for ASME Containers
Designed for use as a primary relief valve on ASME containers such as 250, 500 and 1,000 gallon tanks. Underwriters’ Laboratories lists containers systems on which these types of valves are mounted outside the hood without additional protection, if mounted near the hood and fitted with a protective cap.
| Part Number | Start to Discharge Setting (PSIG) | Container Connection M. NPT | Overall Height (approx.) | Height Above Coupling (approx.) | Wrench Hex Section | Flow Capacity SCFM / Air | Suitable for Tanks with Surface Area Up to:* | Protective Cap (Included) | Order | |
| UL (at 120% of Set Pressure) | ASME (at 120% of Set Pressure) | |||||||||
| 7583G | 250 | 3/4" | 8 3/16" | 1 7/16" | 1 3/4" | 1,980 | 1,806 | 80 Sq. Ft. | 7583-40X | |
| 8684G | 1" | 9 3/8" | 1 9/16" | 1 7/8" | 2,620 | 2,565 | 113 Sq. Ft. | 8684-40 | ||
| 8685G | 1 1/4" | 11 1/16" | 1 11/16" | 2 3/8" | 4,385 | 4,035 | 212 Sq. Ft. | 7585-40X | ||
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME flow rating—whichever is larger.
![]()

Semi-Internal "Pop-Action" Pressure Relief Valves for Large Storage Containers
Designed especially for use as a primary relief valve on large stationary storage containers, these low profile relief valves are generally mounted in half couplings. However, they are designed so that the inlet ports clear the bottom of a full 2" coupling. This assures that the relief valve should always be capable of maximum flow under emergency conditions.
| Part Number | Start to Discharge Setting (PSIG) | Container Connection M. NPT | Flow Capacity SCFM / Air* | Accessories | TEECO | |||
| UL (at 120% of Set Pressure) | ASME (at 120% of Set Pressure) | |||||||
| Suitable for Tanks w/ Surface Area Up to: |
Protective Cap |
Pipeaway Adapter | Order Relief Valves | |||||
| 7534B | 125 | 2" | 6,025 | --- | 319 Sq. Ft. |
7534-40 |
7545-12 | |
| 7534G | 250 | 11,675 | 10,422 | 708 Sq. Ft. | ||||


Products>>Section A- RegO / ECII>>Pressure Relief Valves and Relief Valve Manifolds>>Page A-19